GT-1100(HWS)
Hot Wire Semiconductor Sensor toxic gas detector

FEATURES
- Explosion proof housing (Ex d IIC T6 IP65)
- FND digital display
- 4~20mA DC output
- Hot Wire Semiconductor Sensor
- Calibration using magnetic bar
- Option : Remote or duct type(Model: +R) & Alarm1,Alarm2,Fail relay output(Model: +C)
SPECIFICATION
Model | GX-1100 (HWS) |
Measuring gas | Toxic gases |
Measuring range | ppm |
Detection principle | Hot-wire semiconductor |
Display | 4 digit FND |
Sampling | Diffusion |
Power | 18 to 30V DC |
Power consumption | 3.4W (142mA) |
Output signal | Standard : 4 to 20mA DC (Option1 : RS-485 Modbus / Option2 : Alarm contact) |
Load impedance | 600Ω |
Local calibration | Yes |
Explosion proof | Ex d IIC T6 IP65 |
Detector housing | Aluminum diecasting |
Sensor housing | SUS 316 |
Dimension | 132(W)×148.5(H)×95~98(D) |
Cable | CVVS 1.5SQ, 3wire |
Response time | Less than 15 seconds at T90 |
Zero / span drift | ±2% |
Accuracy | ±2% |
Expected life | 36 to 60 month |
Operating temp. | -20℃ to 50℃ |
ACCESSORIES
Calibration Kits
Adaptor & Splash guard
Weather proof cover&u-bolt
WBH-100 (Horn&Beacon)
Magnetic bar